STIGQter STIGQter: STIG Summary: VMware vRealize Automation 7.x tc Server Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 28 Sep 2018:

tc Server VCO must produce log records containing sufficient information to establish the identity of any user/subject or process associated with an event.

DISA Rule

SV-100621r1_rule

Vulnerability Number

V-89971

Group Title

SRG-APP-000100-WSR-000064

Rule Version

VRAU-TC-000240

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Navigate to and open /etc/vco/app-server/server.xml.

Navigate to and locate <Host>.

Configure the <Host> node with the <AccessLogValve> below.

Note: The "AccessLogValve" should be configured as follows:
<Valve className="org.apache.catalina.valves.AccessLogValve"
directory="logs"
pattern="%h %l %u %t &quot;%r&quot; %s %b"
prefix="localhost_access_log."
suffix=".txt"/>

Check Contents

At the command prompt, execute the following command:

tail /storage/log/vmware/vco/app-server/localhost_access_log.txt

If the identity of the user is not being recorded, this is a finding.

Vulnerability Number

V-89971

Documentable

False

Rule Version

VRAU-TC-000240

Severity Override Guidance

At the command prompt, execute the following command:

tail /storage/log/vmware/vco/app-server/localhost_access_log.txt

If the identity of the user is not being recorded, this is a finding.

Check Content Reference

M