SV-102649r3_rule
V-92561
SRG-APP-000295-WSR-000134
AS24-W2-000650
CAT II
10
Edit the <'INSTALLED PATH'>\conf\httpd.conf file and load the "mod_reqtimeout" module.
Set the "RequestReadTimeout" directive.
The "RequestReadTimeout" directive must be explicitly configured (i.e., not left to a default value) to a value compatible with the organization's operations.
Review the <'INSTALLED PATH'>\conf\httpd.conf file.
Verify the "mod_reqtimeout" is loaded.
If it does not exist, this is a finding.
If the "mod_reqtimeout" module is loaded but the "RequestReadTimeout" directive is not configured, this is a finding.
Note: The "RequestReadTimeout" directive must be explicitly configured (i.e., not left to a default value) to a value compatble with the organization's operations.
V-92561
False
AS24-W2-000650
Review the <'INSTALLED PATH'>\conf\httpd.conf file.
Verify the "mod_reqtimeout" is loaded.
If it does not exist, this is a finding.
If the "mod_reqtimeout" module is loaded but the "RequestReadTimeout" directive is not configured, this is a finding.
Note: The "RequestReadTimeout" directive must be explicitly configured (i.e., not left to a default value) to a value compatble with the organization's operations.
M