SV-207271r615936_rule
V-207271
SRG-APP-000089
EX13-MB-000025
CAT II
10
Open the Exchange Management Shell and enter the following command:
Set-EventLogLevel -Identity <'IdentityName\EventlogName'> -Level Lowest
Note: The <IdentityName\EventlogName> value must be in quotes.
Open the Exchange Management Shell and enter the following command:
Get-EventLogLevel
If Diagnostic of any EventLevel is not set to Lowest, this is a finding.
V-207271
False
EX13-MB-000025
Open the Exchange Management Shell and enter the following command:
Get-EventLogLevel
If Diagnostic of any EventLevel is not set to Lowest, this is a finding.
M
2923