STIGQter STIGQter: STIG Summary: z/OS SRRAUDIT for RACF STIG Version: 6 Release: 4 Benchmark Date: 20 Jan 2015:

SRRAUDIT installation data sets must be properly protected.

DISA Rule

SV-21732r2_rule

Vulnerability Number

V-16932

Group Title

ZB000000

Rule Version

ZSRRR000

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

The IAO will ensure WRITE and/or greater access to SRRAUDIT installation data sets is limited to System Programmers only, and all WRITE and/or greater access is logged. READ access can be given to Security personnel, Production Control and Scheduling personnel, and Auditors. All failures and successful WRITE and/or greater accesses are logged.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have WRITE and/or greater access and, if required, that all WRITE and/or greater accesses are logged. He will identify if any additional groups have WRITE and/or greater access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

(Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.)

Data sets to be protected will be:
SYS2.SRRAUDIT.

The following commands are provided as a sample for implementing data set controls:

ad 'SYS2.SRRAUDIT.**' uacc(none) owner(sys2) -
audit(success(update) failures(read)) -
data('SRRAUDIT Install DS')
pe 'SYS2.SRRAUDIT.**' id(syspaudt tstcaudt) acc(a)
pe 'SYS2.SRRAUDIT.**' id(audtaudt pcspaudt) acc(r)
pe 'SYS2.SRRAUDIT.**' id(secaaudt) acc(r)

setr generic(dataset) refresh

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(SRRPROD)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZSRR0000)

Verify that the accesses to the SRRAUDIT installation data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The RACF data set access authorizations restrict READ access to systems programming personnel, domain level production control and scheduling personnel, security personnel, and auditors.

___ The RACF data set access authorizations restrict WRITE and/or greater access to systems programming personnel.

___ The RACF data set access authorizations specify that all (i.e., failures and successes) WRITE and/or greater accesses are logged.

___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.

Vulnerability Number

V-16932

Documentable

False

Rule Version

ZSRRR000

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(SRRPROD)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZSRR0000)

Verify that the accesses to the SRRAUDIT installation data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The RACF data set access authorizations restrict READ access to systems programming personnel, domain level production control and scheduling personnel, security personnel, and auditors.

___ The RACF data set access authorizations restrict WRITE and/or greater access to systems programming personnel.

___ The RACF data set access authorizations specify that all (i.e., failures and successes) WRITE and/or greater accesses are logged.

___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.

Check Content Reference

M

Responsibility

Systems Programmer

Target Key

1664

Comments