SV-220309r395850_rule
V-220309
SRG-APP-000133-DB-000199
O121-P2-010900
CAT II
10
Install all applications on directories, or pools, separate from the DBMS software library directory. Re-locate any directories or re-install other application software that currently shares the DBMS software library directory to separate directories.
For mainframe-based databases, locate database software and configuration files in separate DASD pools from other mainframe applications.
Review the DBMS software library directory and note other root directories located on the same disk directory or any subdirectories. If any non-DBMS software directories exist on the disk directory, examine or investigate their use.
If any of the directories are used by other applications, including third-party applications that use the DBMS, this is a finding.
Only applications that are required for the functioning and administration, not use, of the DBMS should be located on the same disk directory as the DBMS software libraries.
For databases located on mainframes, confirm that the database and its configuration files are isolated in their own DASD pools.
If database software and database configuration files share DASD with other applications, this is a finding.
V-220309
False
O121-P2-010900
Review the DBMS software library directory and note other root directories located on the same disk directory or any subdirectories. If any non-DBMS software directories exist on the disk directory, examine or investigate their use.
If any of the directories are used by other applications, including third-party applications that use the DBMS, this is a finding.
Only applications that are required for the functioning and administration, not use, of the DBMS should be located on the same disk directory as the DBMS software libraries.
For databases located on mainframes, confirm that the database and its configuration files are isolated in their own DASD pools.
If database software and database configuration files share DASD with other applications, this is a finding.
M
4059