STIGQter STIGQter: STIG Summary: Microsoft Exchange 2016 Edge Transport Server Security Technical Implementation Guide Version: 2 Release: 2 Benchmark Date: 22 Jan 2021:

Exchange Queue monitoring must be configured with threshold and action.

DISA Rule

SV-221209r612603_rule

Vulnerability Number

V-221209

Group Title

SRG-APP-000111

Rule Version

EX16-ED-000080

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Open the Exchange Management Shell and enter the following command:

perfmon

In the left pane, navigate to Performance >> Data Collector Sets >> User Defined.

In left pane, right-click on User Defined >> New >> Data Collector Set and configure the system to use the data collection set for monitoring the queues.

Check Contents

Note: If a third-party application is performing monitoring functions, the reviewer should verify the application is monitoring correctly and mark the vulnerability NA.

Open the Exchange Management Shell and enter the following command:

perfmon

In the left pane, navigate to Performance >> Data Collector Sets >> User Defined.

If no sets are defined or queues are not being monitored, this is a finding.

Vulnerability Number

V-221209

Documentable

False

Rule Version

EX16-ED-000080

Severity Override Guidance

Note: If a third-party application is performing monitoring functions, the reviewer should verify the application is monitoring correctly and mark the vulnerability NA.

Open the Exchange Management Shell and enter the following command:

perfmon

In the left pane, navigate to Performance >> Data Collector Sets >> User Defined.

If no sets are defined or queues are not being monitored, this is a finding.

Check Content Reference

M

Target Key

4079

Comments