The application must provide an immediate warning to the SA and ISSO (at a minimum) when allocated audit record storage volume reaches 75% of repository maximum audit record storage capacity.

DISA Rule

SV-222483r561236_rule

Vulnerability Number

V-222483

Group Title

SRG-APP-000359

Rule Version

APSC-DV-001090

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the application to send an immediate alarm to the application admin/SA and the ISSO when the allocated log storage capacity exceeds 75% of usage or exceeds the capacity value the SA and ISSO have determined will provide adequate time to plan for capacity expansion.

Check Contents

Review system documentation and interview application administrator for details regarding logging configuration.

If the application utilizes a centralized logging system that provides storage capacity alarming, this requirement is not applicable.

Identify application alarming capability relating to storage capacity alarming for the log repository. Coordinate with the appropriate personnel regarding the generation of test alarms.

Review log alarm settings and ensure audit log storage capacity alarming is enabled and set to alarm when the storage threshold exceeds 75% of disk storage capacity or the capacity value the SA and ISSO have determined will provide adequate time to plan for capacity expansion.

Ensure the alarm will be sent to the ISSO and the application administrator when the utilization threshold is exceeded by changing the threshold settings to below the current disk space utilization. An alarm should be triggered at that point and forwarded to the ISSO and the SA/application admin.

If the application is not configured to send an alarm when storage volume exceeds 75% of disc capacity or if the designated alarm recipients did not receive an alarm when the test was conducted, this is a finding.

Vulnerability Number

V-222483

Documentable

False

Rule Version

APSC-DV-001090

Severity Override Guidance

Review system documentation and interview application administrator for details regarding logging configuration.

If the application utilizes a centralized logging system that provides storage capacity alarming, this requirement is not applicable.

Identify application alarming capability relating to storage capacity alarming for the log repository. Coordinate with the appropriate personnel regarding the generation of test alarms.

Review log alarm settings and ensure audit log storage capacity alarming is enabled and set to alarm when the storage threshold exceeds 75% of disk storage capacity or the capacity value the SA and ISSO have determined will provide adequate time to plan for capacity expansion.

Ensure the alarm will be sent to the ISSO and the application administrator when the utilization threshold is exceeded by changing the threshold settings to below the current disk space utilization. An alarm should be triggered at that point and forwarded to the ISSO and the SA/application admin.

If the application is not configured to send an alarm when storage volume exceeds 75% of disc capacity or if the designated alarm recipients did not receive an alarm when the test was conducted, this is a finding.