SV-222485r508029_rule
V-222485
SRG-APP-000108
APSC-DV-001110
CAT II
10
Configure the application to send an alarm in the event the audit system has failed or is failing.
Review system documentation and interview application administrator for details regarding logging configuration.
If the application utilizes a centralized logging system that provides the audit processing failure alarms, this requirement is not applicable.
Identify application alarming capability regarding audit processing failure events.
Verify the application is configured to alarm when the auditing system fails.
Example alarm events include but are not limited to:
hardware failure events
failures to capture audit record events
audit storage errors
If the application is not configured to alarm on alerts that indicate the audit system has failed or is failing, this is a finding.
V-222485
False
APSC-DV-001110
Review system documentation and interview application administrator for details regarding logging configuration.
If the application utilizes a centralized logging system that provides the audit processing failure alarms, this requirement is not applicable.
Identify application alarming capability regarding audit processing failure events.
Verify the application is configured to alarm when the auditing system fails.
Example alarm events include but are not limited to:
hardware failure events
failures to capture audit record events
audit storage errors
If the application is not configured to alarm on alerts that indicate the audit system has failed or is failing, this is a finding.
M
4093