SV-223441r533198_rule
V-223441
SRG-OS-000080-GPOS-00048
ACF2-ES-000200
CAT I
10
Evaluate the impact of correcting any deficiency. Develop a plan of action and implement the changes as required to protect SYS1.UADS.
SYS1.UADS WRITE or Greater authority is limited to the systems programming staff.
READ and/or UPDATE access should be limited to the security staff.
READ access is limited to Auditors when included in the site security plan
Configure allocate access to SYS1.UADS to be limited to system programmers only; Read and Update access to SYS1.UADS to be limited to system programmer personnel and/or security personnel and all dataset access is logged.
The ESM data set rules for SYS1.UADS restricts ALTER access to only z/OS systems programming personnel.
The ESM data set rules for SYS1.UADS restrict READ and/or UPDATE access to z/OS systems programming personnel and/or security personnel.
The ESM data set rules for SYS1.UADS restrict READ access to auditors as documented in Security Plan.
The ESM data set rules for SYS1.UADS specify that all (i.e., failures and successes) data set access authorities (i.e., READ, UPDATE, ALTER, and CONTROL) will be logged.
If all of the above are untrue, this is not a finding.
If any of the above is true, this is a finding.
V-223441
False
ACF2-ES-000200
The ESM data set rules for SYS1.UADS restricts ALTER access to only z/OS systems programming personnel.
The ESM data set rules for SYS1.UADS restrict READ and/or UPDATE access to z/OS systems programming personnel and/or security personnel.
The ESM data set rules for SYS1.UADS restrict READ access to auditors as documented in Security Plan.
The ESM data set rules for SYS1.UADS specify that all (i.e., failures and successes) data set access authorities (i.e., READ, UPDATE, ALTER, and CONTROL) will be logged.
If all of the above are untrue, this is not a finding.
If any of the above is true, this is a finding.
M
4100