SV-223487r533198_rule
V-223487
SRG-OS-000480-GPOS-00227
ACF2-ES-000690
CAT II
10
Configure the BACKUP GSO value to specify a time field and Time(00:00 ) is not specified unless the database is shared and backed up on another system.
CPUID() PRISPACE(5) SECSPACE(5) STRING(S ACFBKUP) TIME(00:01) WORKUNIT(VIO)
Example:
SET C(GSO)
INSERT BACKUP CPUID() PRISPACE(5) SECSPACE(5) STRING(S ACFBKUP) TIME(00:01) WORKUNIT(VIO)
F ACF2,REFRESH(BACKUP)
From the ACF command screen enter:
SET CONTROL(GSO)
LIST LIKE(BACKUP-)
If the GSO BACKUP record values conform to the following requirements, this is not a finding.
Example:
CPUID() PRISPACE(5) SECSPACE(5) STRING(S ACFBKUP) TIME(00:01) WORKUNIT(VIO)
If there is any deviation from the above requirements in the GSO BACKUP record values, this is a finding.
V-223487
False
ACF2-ES-000690
From the ACF command screen enter:
SET CONTROL(GSO)
LIST LIKE(BACKUP-)
If the GSO BACKUP record values conform to the following requirements, this is not a finding.
Example:
CPUID() PRISPACE(5) SECSPACE(5) STRING(S ACFBKUP) TIME(00:01) WORKUNIT(VIO)
If there is any deviation from the above requirements in the GSO BACKUP record values, this is a finding.
M
4100