STIGQter STIGQter: STIG Summary: IBM z/OS ACF2 Security Technical Implementation Guide Version: 8 Release: 2 Benchmark Date: 23 Apr 2021:

IBM z/OS data sets for the Base TCP/IP component must be properly protected.

DISA Rule

SV-223603r533198_rule

Vulnerability Number

V-223603

Group Title

SRG-OS-000080-GPOS-00048

Rule Version

ACF2-TC-000050

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Review the data set access authorizations defined to the ACP for the Base TCP/IP component. Configure these data sets to be protected in accordance with the following rules:

WRITE and ALLOCATE access to product data sets is restricted to systems programming personnel (i.e., SMP/E distribution data sets with the prefix SYS1.TCPIP.AEZA and target data sets with the prefix SYS1.TCPIP. SEZA).

WRITE and ALLOCATE access to the data set(s) containing the Data and Profile configuration files is restricted to systems programming personnel.
Note: If any INCLUDE statements are specified in the Profile configuration file, the named MVS data sets have the same access authorization requirements.

WRITE and ALLOCATE access to the data set(s) containing the Data and Profile configuration files is logged.
Note: If any INCLUDE statements are specified in the Profile configuration file, the named MVS data sets have the same logging requirements.

WRITE and ALLOCATE access to the data set(s) containing the configuration files shared by TCP/IP applications is restricted to systems programming personnel.
Note: For systems running the TSS ACP replace the WRITE and ALLOCATE with WRITE, UPDATE, CREATE, CONTROL, SCRATCH, and ALL.

Check Contents

If all of the following items are true, this is not a finding.

WRITE and ALLOCATE access to product data sets is restricted to systems programming personnel (i.e., SMP/E distribution data sets with the prefix SYS1.TCPIP.AEZA and target data sets with the prefix SYS1.TCPIP.SEZA).

WRITE and ALLOCATE access to the data set(s) containing the Data and Profile configuration files is restricted to systems programming personnel.
Note: If any INCLUDE statements are specified in the Profile configuration file, the named MVS data sets have the same access authorization requirements.

WRITE and ALLOCATE access to the data set(s) containing the Data and Profile configuration files is logged.
Note: If any INCLUDE statements are specified in the Profile configuration file, the named MVS data sets have the same logging requirements.

WRITE and ALLOCATE access to the data set(s) containing the configuration files shared by TCP/IP applications is restricted to systems programming personnel.
Note: For systems running the TSS ACP replace the WRITE and ALLOCATE with WRITE, UPDATE, CREATE, CONTROL, SCRATCH, and ALL.

Vulnerability Number

V-223603

Documentable

False

Rule Version

ACF2-TC-000050

Severity Override Guidance

If all of the following items are true, this is not a finding.

WRITE and ALLOCATE access to product data sets is restricted to systems programming personnel (i.e., SMP/E distribution data sets with the prefix SYS1.TCPIP.AEZA and target data sets with the prefix SYS1.TCPIP.SEZA).

WRITE and ALLOCATE access to the data set(s) containing the Data and Profile configuration files is restricted to systems programming personnel.
Note: If any INCLUDE statements are specified in the Profile configuration file, the named MVS data sets have the same access authorization requirements.

WRITE and ALLOCATE access to the data set(s) containing the Data and Profile configuration files is logged.
Note: If any INCLUDE statements are specified in the Profile configuration file, the named MVS data sets have the same logging requirements.

WRITE and ALLOCATE access to the data set(s) containing the configuration files shared by TCP/IP applications is restricted to systems programming personnel.
Note: For systems running the TSS ACP replace the WRITE and ALLOCATE with WRITE, UPDATE, CREATE, CONTROL, SCRATCH, and ALL.

Check Content Reference

M

Target Key

4100

Comments