STIGQter STIGQter: STIG Summary: BlackBerry UEM Security Technical Implementation Guide Version: 2 Release: 1 Benchmark Date: 22 Jan 2021:

The BlackBerry UEM server must be configured to audit DoD or site-defined auditable events. Note: See VulDiscussion for a list of DoD required auditable events.

DISA Rule

SV-224378r604136_rule

Vulnerability Number

V-224378

Group Title

PP-MDM-411065

Rule Version

BUEM-00-000630

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

On the BlackBerry UEM console, do the following:
1. On the menu bar, click Settings >> Infrastructure >> Audit settings.
2. In the right pane, click the edit icon.
3. To add security events to audit, click + . Select the events and click Add.
4. Select each event in each event category from the list below.
5. In the Setting column, insure "all" has been selected for each event that has this selection available.
6. Click Save.

Required events: all "Enrollment" events, all "Policy" events, all "Server" events, all "System" related events, and all "Application" events

Check Contents

Review the list of audit events:
1. In the UEM console go to Settings >> Infrastructure >> Audit settings
2. Verify all required events are listed and "setting" is set to "All" for all events where this selection is available.

Note: Events are organized by category. All events for each required event category should be selected (see the list below).

If all required events are not listed and "setting" is not set to "All" for all events where this selection is available, this is a finding.

Required events: all "Enrollment" events, all "Policy" events, all "Server" events, all "System" related events, and all "Application" events

Vulnerability Number

V-224378

Documentable

False

Rule Version

BUEM-00-000630

Severity Override Guidance

Review the list of audit events:
1. In the UEM console go to Settings >> Infrastructure >> Audit settings
2. Verify all required events are listed and "setting" is set to "All" for all events where this selection is available.

Note: Events are organized by category. All events for each required event category should be selected (see the list below).

If all required events are not listed and "setting" is not set to "All" for all events where this selection is available, this is a finding.

Required events: all "Enrollment" events, all "Policy" events, all "Server" events, all "System" related events, and all "Application" events

Check Content Reference

M

Target Key

4134

Comments