Motorola Android Pie must be configured to disallow configuration of date and time.

DISA Rule

SV-230139r569707_rule

Vulnerability Number

V-230139

Group Title

GOOG-09-010200

Rule Version

MOTO-09-010200

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure Motorola Android Pie Work Profile to set auto network time.

On the MDM console, in the Android user restrictions section, set "Set auto (network) time required" to "On".

Check Contents

Review the Motorola Android Pie Work Profile to confirm that user configuration of date and time is not allowed.

This procedure is performed on both the MDM Administration console and the Motorola Android Pie device.

On the MDM console, verify that "Set auto (network) time required" is set to "On".

On the Android Pie device:
1. Open Settings.
2. Tap "System".
3. Tap "Date & times".
4. Verify that "Automatic date & time" is grayed out.

If on the MDM console "Set auto (network) time required" is not set to "On", or on the Motorola Android Pie device, "Automatic date & time" is grayed out, this is a finding.

Vulnerability Number

V-230139

Documentable

False

Rule Version

MOTO-09-010200

Severity Override Guidance

Review the Motorola Android Pie Work Profile to confirm that user configuration of date and time is not allowed.

This procedure is performed on both the MDM Administration console and the Motorola Android Pie device.

On the MDM console, verify that "Set auto (network) time required" is set to "On".

On the Android Pie device:
1. Open Settings.
2. Tap "System".
3. Tap "Date & times".
4. Verify that "Automatic date & time" is grayed out.

If on the MDM console "Set auto (network) time required" is not set to "On", or on the Motorola Android Pie device, "Automatic date & time" is grayed out, this is a finding.