STIGQter STIGQter: STIG Summary: Unified Endpoint Management Server Security Requirements Guide Version: 1 Release: 1 Benchmark Date: 20 Nov 2020:

The UEM server must, when a component failure is detected, activate an organization-defined alarm and/or automatically shut down the application or the component.

DISA Rule

SV-234426r617355_rule

Vulnerability Number

V-234426

Group Title

SRG-APP-000268

Rule Version

SRG-APP-000268-UEM-000153

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the UEM server to activate an organization-defined alarm and/or automatically shut down the application or the component when a component failure is detected.

Check Contents

Verify the UEM server, when a component failure is detected, activates an organization-defined alarm and/or automatically shuts down the application or the component.

If the UEM server, when a component failure is detected, does not activate an organization-defined alarm and/or automatically shut down the application or the component, this is a finding.

Vulnerability Number

V-234426

Documentable

False

Rule Version

SRG-APP-000268-UEM-000153

Severity Override Guidance

Verify the UEM server, when a component failure is detected, activates an organization-defined alarm and/or automatically shuts down the application or the component.

If the UEM server, when a component failure is detected, does not activate an organization-defined alarm and/or automatically shut down the application or the component, this is a finding.

Check Content Reference

M

Target Key

5269

Comments