STIGQter STIGQter: STIG Summary: Honeywell Android 9.x COBO Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 14 Jan 2021:

The Honeywell Mobility Edge Android Pie device must be configured to enforce a minimum password length of six characters.

DISA Rule

SV-235035r626530_rule

Vulnerability Number

V-235035

Group Title

PP-MDF-301010

Rule Version

HONW-09-000100

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the Honeywell Android device to enforce a minimum password length of six characters.

On the MDM console:
1. Open password requirements.
2. Open device password section.
3. Enter in the number of characters as "6".

Check Contents

Review Honeywell Android device configuration settings to determine if the mobile device is enforcing a minimum password length of six characters.

This validation procedure is performed on both the MDM Administration console and the Android Pie device.

On the MDM console:
1. Open password requirements.
2. Open device password section.
3. Ensure the minimum password length is set to "6" characters.

On the Honeywell Android Pie device:
1. Open Settings >> Security & location >> Screen lock.
2. Enter current password.
3. Tap on "Password".
4. Verify Password length listed is at least "6".

If the device password length is not set to six characters or more on the MDM console or on the Honeywell Android Pie device, this is a finding.

Vulnerability Number

V-235035

Documentable

False

Rule Version

HONW-09-000100

Severity Override Guidance

Review Honeywell Android device configuration settings to determine if the mobile device is enforcing a minimum password length of six characters.

This validation procedure is performed on both the MDM Administration console and the Android Pie device.

On the MDM console:
1. Open password requirements.
2. Open device password section.
3. Ensure the minimum password length is set to "6" characters.

On the Honeywell Android Pie device:
1. Open Settings >> Security & location >> Screen lock.
2. Enter current password.
3. Tap on "Password".
4. Verify Password length listed is at least "6".

If the device password length is not set to six characters or more on the MDM console or on the Honeywell Android Pie device, this is a finding.

Check Content Reference

M

Target Key

5275

Comments