STIGQter STIGQter: STIG Summary: Honeywell Android 9.x COBO Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 14 Jan 2021:

The Honeywell Mobility Edge Android Pie device must be configured to not allow passwords that include more than two repeating or sequential characters.

DISA Rule

SV-235036r626530_rule

Vulnerability Number

V-235036

Group Title

PP-MDF-301020

Rule Version

HONW-09-000200

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the Honeywell Android device to prevent passwords from containing more than two repeating or sequential characters.

On the MDM console:
1. Open password requirements.
2. Open device password section.
3. Set password quality to "Numeric (Complex)".

NOTE: Alphabetic, Alphanumeric, and Complex are also acceptable selections, but these will cause the user to select a complex password, which is not required by the STIG.

Check Contents

Review Honeywell Android device configuration settings to determine if the mobile device is prohibiting passwords with more than two repeating or sequential characters.

This validation procedure is performed on both the MDM Administration console and the Android Pie device.

On the MDM console:
1. Open password requirements.
2. Open device password section.
3. Ensure the password quality is set to "Numeric (Complex)".

On the Honeywell Android Pie device:
1. Open Settings >> Security & location >> Screen lock.
2. Enter current password.
3. Tap on "Password".
4. Verify Password complexity requirements are listed: Must contain at least 1 letter.

If the MDM console device policy is set to a password with more than two repeating or sequential characters or on the Honeywell Android Pie device, the device policy is set to a password with more than two repeating or sequential characters, this is a finding.

NOTE: Alphabetic, Alphanumeric, and Complex are also acceptable selections, but these will cause the user to select a complex password, which is not required by the STIG.

Vulnerability Number

V-235036

Documentable

False

Rule Version

HONW-09-000200

Severity Override Guidance

Review Honeywell Android device configuration settings to determine if the mobile device is prohibiting passwords with more than two repeating or sequential characters.

This validation procedure is performed on both the MDM Administration console and the Android Pie device.

On the MDM console:
1. Open password requirements.
2. Open device password section.
3. Ensure the password quality is set to "Numeric (Complex)".

On the Honeywell Android Pie device:
1. Open Settings >> Security & location >> Screen lock.
2. Enter current password.
3. Tap on "Password".
4. Verify Password complexity requirements are listed: Must contain at least 1 letter.

If the MDM console device policy is set to a password with more than two repeating or sequential characters or on the Honeywell Android Pie device, the device policy is set to a password with more than two repeating or sequential characters, this is a finding.

NOTE: Alphabetic, Alphanumeric, and Complex are also acceptable selections, but these will cause the user to select a complex password, which is not required by the STIG.