SV-235036r626530_rule
V-235036
PP-MDF-301020
HONW-09-000200
CAT II
10
Configure the Honeywell Android device to prevent passwords from containing more than two repeating or sequential characters.
On the MDM console:
1. Open password requirements.
2. Open device password section.
3. Set password quality to "Numeric (Complex)".
NOTE: Alphabetic, Alphanumeric, and Complex are also acceptable selections, but these will cause the user to select a complex password, which is not required by the STIG.
Review Honeywell Android device configuration settings to determine if the mobile device is prohibiting passwords with more than two repeating or sequential characters.
This validation procedure is performed on both the MDM Administration console and the Android Pie device.
On the MDM console:
1. Open password requirements.
2. Open device password section.
3. Ensure the password quality is set to "Numeric (Complex)".
On the Honeywell Android Pie device:
1. Open Settings >> Security & location >> Screen lock.
2. Enter current password.
3. Tap on "Password".
4. Verify Password complexity requirements are listed: Must contain at least 1 letter.
If the MDM console device policy is set to a password with more than two repeating or sequential characters or on the Honeywell Android Pie device, the device policy is set to a password with more than two repeating or sequential characters, this is a finding.
NOTE: Alphabetic, Alphanumeric, and Complex are also acceptable selections, but these will cause the user to select a complex password, which is not required by the STIG.
V-235036
False
HONW-09-000200
Review Honeywell Android device configuration settings to determine if the mobile device is prohibiting passwords with more than two repeating or sequential characters.
This validation procedure is performed on both the MDM Administration console and the Android Pie device.
On the MDM console:
1. Open password requirements.
2. Open device password section.
3. Ensure the password quality is set to "Numeric (Complex)".
On the Honeywell Android Pie device:
1. Open Settings >> Security & location >> Screen lock.
2. Enter current password.
3. Tap on "Password".
4. Verify Password complexity requirements are listed: Must contain at least 1 letter.
If the MDM console device policy is set to a password with more than two repeating or sequential characters or on the Honeywell Android Pie device, the device policy is set to a password with more than two repeating or sequential characters, this is a finding.
NOTE: Alphabetic, Alphanumeric, and Complex are also acceptable selections, but these will cause the user to select a complex password, which is not required by the STIG.
M
5275