STIGQter STIGQter: STIG Summary: Oracle WebLogic Server 12c Security Technical Implementation Guide Version: 2 Release: 1 Benchmark Date: 23 Apr 2021:

Oracle WebLogic must use internal system clocks to generate time stamps for audit records.

DISA Rule

SV-235954r628640_rule

Vulnerability Number

V-235954

Group Title

SRG-APP-000116-AS-000076

Rule Version

WBLC-02-000093

Severity

CAT III

CCI(s)

Weight

10

Fix Recommendation

1. Access EM
2. Select the domain from the navigation tree, and use the dropdown to select 'WebLogic Domain' -> 'Security' -> 'Security Provider Configuration'
3. Beneath 'Audit Service' section, click 'Configure' button
4. Set the 'Timezone Settings' radio button to 'UTC' so audit logs will be time stamped in Coordinated Universal Time regardless of the time zone of the underlying physical or virtual machine
5. The time stamp will be recorded according to the operating system's set time
6. Click 'Apply' and restart the servers in the WebLogic domain

Check Contents

1. Access EM
2. Select the domain from the navigation tree, and use the dropdown to select 'WebLogic Domain' -> 'Security' -> 'Security Provider Configuration'
3. Beneath 'Audit Service' section, click 'Configure' button
4. Ensure the 'Timezone Settings' radio button is set to 'UTC' so audit logs will be time stamped in Coordinated Universal Time regardless of the time zone of the underlying physical or virtual machine
5. The time stamp will be recorded according to the operating system's set time

If the 'Timezone Settings' radio button is not set to 'UTC', this is a finding.

Vulnerability Number

V-235954

Documentable

False

Rule Version

WBLC-02-000093

Severity Override Guidance

1. Access EM
2. Select the domain from the navigation tree, and use the dropdown to select 'WebLogic Domain' -> 'Security' -> 'Security Provider Configuration'
3. Beneath 'Audit Service' section, click 'Configure' button
4. Ensure the 'Timezone Settings' radio button is set to 'UTC' so audit logs will be time stamped in Coordinated Universal Time regardless of the time zone of the underlying physical or virtual machine
5. The time stamp will be recorded according to the operating system's set time

If the 'Timezone Settings' radio button is not set to 'UTC', this is a finding.