SV-239322r674895_rule
V-239322
SRG-OS-000480-VMM-002000
ESXI-67-000068
CAT II
10
Note that this check refers to an entity outside the scope of the ESXi server system.
Remove any VLANs trunked across physical ports connected to ESXi hosts that are not in use.
Note that this check refers to an entity outside the physical scope of the ESXi server system. The configuration of upstream physical switches must be documented to ensure that unneeded VLANs are configured for all physical ports connected to ESXi hosts.
Inspect the documentation and verify that the documentation is updated according to an organization-defined frequency and/or whenever modifications are made to either ESXi hosts or the upstream physical switches.
Alternatively, log in to the physical switch and verify that only needed VLANs are configured for all physical ports connected to ESXi hosts.
If the physical switch's configuration is trunked VLANs that are not used by ESXi for all physical ports connected to ESXi hosts, this is a finding.
V-239322
False
ESXI-67-000068
Note that this check refers to an entity outside the physical scope of the ESXi server system. The configuration of upstream physical switches must be documented to ensure that unneeded VLANs are configured for all physical ports connected to ESXi hosts.
Inspect the documentation and verify that the documentation is updated according to an organization-defined frequency and/or whenever modifications are made to either ESXi hosts or the upstream physical switches.
Alternatively, log in to the physical switch and verify that only needed VLANs are configured for all physical ports connected to ESXi hosts.
If the physical switch's configuration is trunked VLANs that are not used by ESXi for all physical ports connected to ESXi hosts, this is a finding.
M
5326