STIGQter STIGQter: STIG Summary: z/OS VSS for RACF STIG Version: 6 Release: 7 Benchmark Date: 22 Jul 2016:

Vanguard Security Solutions (VSS) Install data sets are not properly protected.

DISA Rule

SV-24657r1_rule

Vulnerability Number

V-16932

Group Title

ZB000000

Rule Version

ZVSSR000

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

The IAO will ensure that update and alter access to program product install data sets is limited to System Programmers, and read access is limited to Security personnel and Auditors, and all update and allocate access is logged.

The installing System Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program ) active on the system.

Data set prefix to be protected will be:

SYS2.VSS.
SYS2A.VSS.
SYS3.VSS.VANOPTS

The following commands are provided as a sample for implementing dataset controls:

ad 'sys2.vss.**' uacc(none) owner(sys2) -
audit(success(update) failures(read)) -
data('Vendor DS Profile: Vanguard Security Solutions')
pe 'sys2.vss.**' id(syspaudt) acc(a)
pe 'sys2.vss.**' id(secaaudt secdaudt audtaudt) acc(r)

ad 'sys2a.vss.**' uacc(none) owner(sys2a) -
audit(success(update) failures(read)) -
data('Vendor Loadlib: Vanguard Security Solutions')
pe 'sys2a.vss.**' id(syspaudt) acc(a)
pe 'sys2a.vss.**' id(secaaudt secdaudt audtaudt) acc(r)

ad 'sys3.vss.vanopts.**' uacc(none) owner(sys3) -
audit(success(update) failures(read)) -
data('Site Customized DS Profile: Vanguard Security Solutions')
pe 'sys3.vss.vanopts.**' id(syspaudt) acc(a)
pe 'sys3.vss.vanopts.**' id(secaaudt secdaudt audtaudt) acc(r)

Check Contents

a) Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(VSSRPT)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZVSS0000)

b) Verify that access to the Vanguard Security Solutions (VSS) Install data sets are properly restricted.

___ The RACF data set rules for the product install data sets do not restrict UPDATE and/or ALTER access to systems programming personnel.

___ The RACF data set rules for the product install data sets do not restrict READ access to systems programming personnel, security personnel and auditors.

___ The RACF data set rules for the product install data sets do not specify that all (i.e., failures and successes) UPDATE and/or ALTER access will be logged.

c) If all of the above are untrue, there is NO FINDING.

d) If any of the above is true, this is a FINDING.

Vulnerability Number

V-16932

Documentable

False

Rule Version

ZVSSR000

Severity Override Guidance

a) Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(VSSRPT)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZVSS0000)

b) Verify that access to the Vanguard Security Solutions (VSS) Install data sets are properly restricted.

___ The RACF data set rules for the product install data sets do not restrict UPDATE and/or ALTER access to systems programming personnel.

___ The RACF data set rules for the product install data sets do not restrict READ access to systems programming personnel, security personnel and auditors.

___ The RACF data set rules for the product install data sets do not specify that all (i.e., failures and successes) UPDATE and/or ALTER access will be logged.

c) If all of the above are untrue, there is NO FINDING.

d) If any of the above is true, this is a FINDING.

Check Content Reference

M

Responsibility

Information Assurance Officer

Target Key

1666

Comments