The ROSCOE system programmer and the IAO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP.
A unique userid must be assigned for the ROSCOE started task(s) thru a corresponding STARTED class entry.
The following sample set of commands is shown here as a guideline:
rdef started ROSCOE.** uacc(none) owner(admin) audit(all(read)) stdata(user(ROSCOE) group(stc))
setr racl(started) ref
Refer to the following report produced by the RACF Data Collection:
- DSMON.RPT(RACSPT)
Automated Analysis
Refer to the following report produced by the RACF Data Collection:
- PDI(ZROS0032)
Verify that the ROSCOE started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry.
V-17454
False
ZROSR032
Refer to the following report produced by the RACF Data Collection:
- DSMON.RPT(RACSPT)
Automated Analysis
Refer to the following report produced by the RACF Data Collection:
- PDI(ZROS0032)
Verify that the ROSCOE started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry.