SV-28469r1_rule
V-16932
ZB000000
ZTADA000
CAT II
10
The IAO will ensure that update and allocate access to program product data sets is limited to System Programmers only, and all update and allocate access is logged. Auditors should have read access.
The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program ) active on the system.
Data sets to be protected will be:
SYS2.TADZ
SYS2.TADZ .V-.SHSIMOD1
SYS3.TADZ
The following commands are provided as a sample for implementing dataset controls:
$KEY(SYS2)
TADZ.- UID(syspaudt) R(A) W(L) A(L) E(A)
TADZ.V-.SHSIMOD1 UID(syspaudt) R(A) W(L) A(L) E(A)
TADZ.- UID(audtaudt) R(A) E(A)
$KEY(SYS3)
TADZ.- UID(syspaudt) R(A) W(L) A(L) E(A)
TADZ.- UID(audtaudt) R(A) E(A)
a) Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(TADZRPT)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZTAD0000)
b) Verify that access to the TADz Install data sets are properly restricted.
___ The ACF2 data set rules for the data sets does not restrict UPDATE and/or ALTER access to systems programming personnel.
___ The ACF2 data set rules for the data sets does not specify that all (i.e., failures and successes) UPDATE and/or ALTER access will be logged.
c) If all of the above are untrue, there is NO FINDING.
d) If any of the above is true, this is a FINDING.
V-16932
False
ZTADA000
a) Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(TADZRPT)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZTAD0000)
b) Verify that access to the TADz Install data sets are properly restricted.
___ The ACF2 data set rules for the data sets does not restrict UPDATE and/or ALTER access to systems programming personnel.
___ The ACF2 data set rules for the data sets does not specify that all (i.e., failures and successes) UPDATE and/or ALTER access will be logged.
c) If all of the above are untrue, there is NO FINDING.
d) If any of the above is true, this is a FINDING.
M
Systems Programmer
1858