SV-30545r1_rule
V-16932
ZB000000
ZHCDR000
CAT II
10
The IAO will ensure that update and allocate access to IBM Hardware Configuration Definition (HCD) install data sets is limited to System Programmers only, and all update and alter access is logged. Auditors, automated operations, and operators should have READ access.
The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.
Data sets to be protected will be:
SYS1.SCBD*
The following commands are provided as a sample for implementing dataset controls:
ad 'SYS1.SCBD*.**' uacc(none) owner(sys1) -
audit(success(update) failures(read)) -
data('Vendor DS Profile: hcd')
pe 'SYS1.SCBD*.**' id(syspaudt tstcaudt) acc(a)
pe 'SYS1.SCBD*.**' id(audtaudt autoaudt operaudt) acc(r)
setr generic(dataset) refresh
Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(HCDRPT)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZHCD0000)
Verify that access to the IBM Hardware Configuration Definition (HCD) install data sets are properly restricted.
___ The RACF data set rules for the data sets restricts READ access to auditors, automated operations, operators, and systems programming personnel.
___ The RACF data set rules for the data sets restricts UPDATE and/or ALTER access to systems programming personnel.
___ The RACF data set rules for the data sets specifies that all (i.e., failures and successes) UPDATE and/or ALTER access are logged.
V-16932
False
ZHCDR000
Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(HCDRPT)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZHCD0000)
Verify that access to the IBM Hardware Configuration Definition (HCD) install data sets are properly restricted.
___ The RACF data set rules for the data sets restricts READ access to auditors, automated operations, operators, and systems programming personnel.
___ The RACF data set rules for the data sets restricts UPDATE and/or ALTER access to systems programming personnel.
___ The RACF data set rules for the data sets specifies that all (i.e., failures and successes) UPDATE and/or ALTER access are logged.
M
Systems Programmer
1899