STIGQter STIGQter: STIG Summary: z/OS BMC IOA for RACF STIG Version: 6 Release: 7 Benchmark Date: 26 Oct 2018:

BMC IOA installation data sets will be properly protected.

DISA Rule

SV-31825r2_rule

Vulnerability Number

V-16932

Group Title

ZB000000

Rule Version

ZIOAR000

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

The IAO will ensure that WRITE and/or greater access to BMC IOA installation data sets are limited to System Programmers only. READ access can be given to auditors, BMC users, operations, production control and scheduling personnel, and BMC STCs and/or batch users. All failures and successful WRITE and/or greater accesses are logged.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

(Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.)

Data sets to be protected will be:
SYS2.IOA.*.IOAI.

The following commands are provided as a sample for implementing data set controls:

ad 'SYS2.IOA.*.IOAI.**' uacc(none) owner(SYS2) -
audit(success(update) failures(read)) -
data('BMC IOA Install DS')

pe 'SYS2.IOA.*.IOAI.**' id(<syspaudt> <tstcaudt>) acc(a)
pe 'SYS2.IOA.*.IOAI.**' id(<audtaudt> <bmcuser> <operaudt>) acc(r)
pe 'SYS2.IOA.*.IOAI.**' id(<pcspaudt> BMC STCs) acc(r)

setr generic(dataset) refresh

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(IOARPT)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZIOA0000)

Verify that the accesses to the BMC IOA installation data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The RACF data set access authorizations restrict READ access to auditors, BMC users, operations, production control and scheduling personnel, and BMC STCs and/or batch users.

___ The RACF data set access authorizations restrict WRITE and/or greater access to systems programming personnel.

___ The RACF data set access authorizations specify that all (i.e., failures and successes) WRITE and/or greater access are logged.

___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.

Vulnerability Number

V-16932

Documentable

False

Rule Version

ZIOAR000

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(IOARPT)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZIOA0000)

Verify that the accesses to the BMC IOA installation data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The RACF data set access authorizations restrict READ access to auditors, BMC users, operations, production control and scheduling personnel, and BMC STCs and/or batch users.

___ The RACF data set access authorizations restrict WRITE and/or greater access to systems programming personnel.

___ The RACF data set access authorizations specify that all (i.e., failures and successes) WRITE and/or greater access are logged.

___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.

Check Content Reference

M

Responsibility

Systems Programmer

Target Key

2002

Comments