STIGQter STIGQter: STIG Summary: z/OS BMC CONTROL-O for TSS STIG Version: 6 Release: 7 Benchmark Date: 26 Oct 2018:

BMC CONTROL-O STC data sets must be properly protected.

DISA Rule

SV-31945r4_rule

Vulnerability Number

V-17067

Group Title

ZB000001

Rule Version

ZCTOT001

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

The ISSO will ensure that WRITE and/or greater access to BMC CONTROL-O STC data sets are limited to System Programmers only. UPDATE access can be given to BMC users and the BMC STCs and/or batch users. READ access can be given to auditors, operators, and domain level production control and scheduling personnel.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have what type of access and if required which type of access is logged. The installing systems programmer will identify any additional groups requiring access to specific data sets, and once documented the installing systems programmer will work with the ISSO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

(Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.)

Data sets to be protected will be:
SYS3.IOA.*.CTOO.

The following commands are provided as a sample for implementing data set controls:

TSS PERMIT(<syspaudt>) DSN(SYS3.IOA.*.CTOO.) ACCESS(ALL)
TSS PERMIT(CONTROLO) DSN(SYS3.IOA.*.CTOO.) ACCESS(UPDATE)
TSS PERMIT(<bmcuser>) DSN(SYS3.IOA.*.CTOO.) ACCESS(UPDATE)
TSS PERMIT(<audtaudt>) DSN(SYS3.IOA.*.CTOO.) ACCESS(READ)
TSS PERMIT(<operaudt>) DSN(SYS3.IOA.*.CTOO.) ACCESS(READ)
TSS PERMIT(<pcspaudt>) DSN(SYS3.IOA.*.CTOO.) ACCESS(READ)

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(CTOSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZCTO0001)

Verify that the accesses to the BMC CONTROL-O STC data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The TSS data set access authorizations restrict READ access to auditors, operators, and domain level production control and scheduling personnel.

___ The TSS data set access authorizations restrict WRITE and/or greater access to systems programming personnel.

___ The TSS data set access authorizations restrict UPDATE access to the BMC users and BMC STCs and/or batch users.

Vulnerability Number

V-17067

Documentable

False

Rule Version

ZCTOT001

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(CTOSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZCTO0001)

Verify that the accesses to the BMC CONTROL-O STC data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The TSS data set access authorizations restrict READ access to auditors, operators, and domain level production control and scheduling personnel.

___ The TSS data set access authorizations restrict WRITE and/or greater access to systems programming personnel.

___ The TSS data set access authorizations restrict UPDATE access to the BMC users and BMC STCs and/or batch users.

Check Content Reference

M

Target Key

2001

Comments