STIGQter STIGQter: STIG Summary: z/OS BMC IOA for ACF2 STIG Version: 6 Release: 7 Benchmark Date: 26 Oct 2018:

BMC IOA STC data sets must be properly protected.

DISA Rule

SV-31946r3_rule

Vulnerability Number

V-17067

Group Title

ZB000001

Rule Version

ZIOAA001

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Ensure that WRITE and/or greater access to BMC IOA STC data sets are limited to System Programmers only. UPDATE access can be given to BMC STCs, batch users and BMC administrators. READ access can be given to auditors and BMC users.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged.

The installing System Programmer will identify if any additional groups have update and/or alter access for specific data sets, and once documented will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

(Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.)

Data sets to be protected will be:

SYS3.IOA.*.IOAO.

The following commands are provided as a sample for implementing data set controls:

$KEY(SYS3)
IOA.-.IOAO.- UID(<syspaudt>) R(A) W(A) A(A) E(A)
IOA.-.IOAO.- UID(<tstcaudt>) R(A) W(A) A(A) E(A)
IOA.-.IOAO.- UID(BMC STCs) R(A) W(A) E(A)
IOA.-.IOAO.- UID(<bmcadmin>)R(A) W(A) E(A)
IOA.-.IOAO.- UID(<audtaudt>)R(A) E(A)
IOA.-.IOAO.- UID(<bmcuser>) R(A) E(A

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(IOASTC)

Automated Analysis

Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZIOA0001)

Verify that the accesses to the BMC IOA STC data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The ACF2 data set access authorizations restrict READ access to auditors and BMC users

___ The ACF2 data set access authorizations restrict WRITE and/or greater access to systems programming personnel.

___ The ACF2 data set access authorizations restrict UPDATE access to the BMC STCs, batch users and BMC administrators.

Vulnerability Number

V-17067

Documentable

False

Rule Version

ZIOAA001

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(IOASTC)

Automated Analysis

Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZIOA0001)

Verify that the accesses to the BMC IOA STC data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The ACF2 data set access authorizations restrict READ access to auditors and BMC users

___ The ACF2 data set access authorizations restrict WRITE and/or greater access to systems programming personnel.

___ The ACF2 data set access authorizations restrict UPDATE access to the BMC STCs, batch users and BMC administrators.

Check Content Reference

M

Responsibility

Systems Programmer

Target Key

2002

Comments