SV-32069r1_rule
V-17452
ZB000030
ZCTDT030
CAT II
10
The BMC CONTROL-D system programmer and the IAO will ensure that a product's Started Task(s) is properly Identified / defined to the System ACP.
If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes.
Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified.
A sample is provided here:
TSS CREATE(CONTROLD) TYPE(USER) -
NAME('*STC* for CONTROL-D') DEPT(xxxx) -
FAC(STC) -
MASTFAC(CONTROLD) PASS(xxxxxxxx,0) -
SOURCE(INTRDR) NOSUSPEND
Refer to the following report produced by the TSS Data Collection:
- TSSCMDS.RPT(@ACIDS)
Review each BMC CONTROL-D STC/Batch ACID(s) for the following:
___ Defined with Facility of STC and/or BATCH.
___ Defined with Master Facility of CONTROLD.
___ Is sourced to the INTRDR.
V-17452
False
ZCTDT030
Refer to the following report produced by the TSS Data Collection:
- TSSCMDS.RPT(@ACIDS)
Review each BMC CONTROL-D STC/Batch ACID(s) for the following:
___ Defined with Facility of STC and/or BATCH.
___ Defined with Master Facility of CONTROLD.
___ Is sourced to the INTRDR.
M
Information Assurance Officer
1998