STIGQter STIGQter: STIG Summary: z/OS BMC IOA for RACF STIG Version: 6 Release: 7 Benchmark Date: 26 Oct 2018:

BMC IOA User data sets will be properly protected

DISA Rule

SV-32153r2_rule

Vulnerability Number

V-21592

Group Title

ZB000002

Rule Version

ZIOAR002

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

The IAO will ensure that WRITE and/or greater access to BMC IOA User data sets are limited to System Programmers and/or BMC STCs and/or batch users only. UPDATE access can be given to production control and scheduling personnel and the BMC users. READ access can be given to auditors.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

(Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.)

Data sets to be protected will be:
SYS3.IOA.*.IOAC.

The following commands are provided as a sample for implementing data set controls:

ad 'SYS3.IOA.*.IOAC.**' uacc(none) owner(SYS3) -
audit(failures(read)) -
data('BMC IOA User DS')

pe 'SYS3.IOA.*.IOAC.**' id(<syspaudt> <tstcaudt> BMC STCs) acc(a)
pe 'SYS3.IOA.*.IOAC.**' id(<bmcuser> <pcspaudt>) acc(u)
pe 'SYS3.IOA.*.IOAC.**' id(<audtaudt>) acc(r)

setr generic(dataset) refresh

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(IOAUSER)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZIOA0002)

Verify that the accesses to the BMC IOA User data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The RACF data set access authorizations restricts READ access to auditors.

___ The RACF data set access authorizations restricts WRITE and/or greater access to systems programming personnel.

___ The RACF data set access authorizations restricts WRITE and/or greater access to the BMC STCs and/or batch users.

___ The RACF data set access authorizations restricts UPDATE access to production control and scheduling personnel and the BMC users.

___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.

Vulnerability Number

V-21592

Documentable

False

Rule Version

ZIOAR002

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(IOAUSER)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZIOA0002)

Verify that the accesses to the BMC IOA User data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The RACF data set access authorizations restricts READ access to auditors.

___ The RACF data set access authorizations restricts WRITE and/or greater access to systems programming personnel.

___ The RACF data set access authorizations restricts WRITE and/or greater access to the BMC STCs and/or batch users.

___ The RACF data set access authorizations restricts UPDATE access to production control and scheduling personnel and the BMC users.

___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.

Check Content Reference

M

Responsibility

Systems Programmer

Target Key

2002

Comments