SV-32165r3_rule
V-17067
ZB000001
ZCTDA001
CAT II
10
The IAO will ensure that WRITE and/or greater access to BMC CONTROL-D STC data sets are limited to System Programmers and BMC STCs and/or batch users. UPDATE access can be given to centralized and decentralized security personnel. READ access can be given to auditors and BMC users.
The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.
(Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.)
Data sets to be protected will be:
SYS3.IOA.*.CTDO.
The following commands are provided as a sample for implementing data set controls:
$KEY(SYS3)
IOA.-.CTDO.- UID(syspaudt) R(A) W(A) A(A) E(A)
IOA.-.CTDO.- UID(tstcaudt) R(A) W(A) A(A) E(A)
IOA.-.CTDO.- UID(BMC STCs) R(A) W(A) A(A) E(A)
IOA.-.CTDO.- UID(secaaudt) R(A) W(A) E(A)
IOA.-.CTDO.- UID(secdaudt) R(A) W(A) E(A)
IOA.-.CTDO.- UID(audtaudt) R(A) E(A)
IOA.-.CTDO.- UID(bmcuser) R(A) E(A)
Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(CTDSTC)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZCTD0001)
Verify that the accesses to the BMC CONTROL-D STC data sets are properly restricted. If the following guidance is true, this is not a finding.
___ The ACF2 data set access authorizations restrict READ access to auditors and CONTROL-D end users.
___ The ACF2 data set access authorizations restrict WRITE and/or greater access to systems programming personnel.
___ The ACF2 data set access authorizations restrict WRITE and/or greater access to BMC STCs and/or batch users.
___ The ACF2 data set access authorizations restrict UPDATE access to centralized and decentralized security personnel.
V-17067
False
ZCTDA001
Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(CTDSTC)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZCTD0001)
Verify that the accesses to the BMC CONTROL-D STC data sets are properly restricted. If the following guidance is true, this is not a finding.
___ The ACF2 data set access authorizations restrict READ access to auditors and CONTROL-D end users.
___ The ACF2 data set access authorizations restrict WRITE and/or greater access to systems programming personnel.
___ The ACF2 data set access authorizations restrict WRITE and/or greater access to BMC STCs and/or batch users.
___ The ACF2 data set access authorizations restrict UPDATE access to centralized and decentralized security personnel.
M
Systems Programmer
1998