SV-32206r1_rule
V-21592
ZB000002
ZADTR002
CAT II
10
The IAO will ensure that update and alter access to CA Auditor User data sets are limited to System Programmers, security personnel and auditors.
The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and alter access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.
Data sets to be protected will be:
SYS3.EXAMINE
The following commands are provided as a sample for implementing data set controls:
ad 'SYS3.EXAMINE.**' uacc(none) owner(sys3) -
audit(failures(read)) -
data('Vendor DS Profile: CA Auditor')
pe 'SYS3.EXAMINE.**' id(<syspaudt>) acc(a)
pe 'SYS3.EXAMINE.**' id(<audtaudt> <secaaudt>) acc(A)
setr generic(dataset) refresh
Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(ADTUSER)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZADT0002)
Verify that the accesses to the CA Auditor User data sets are properly restricted.
___ The RACF data set rules for the data sets restricts UPDATE and/or ALTER access to systems programming personnel, security personnel and auditors.
V-21592
False
ZADTR002
Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(ADTUSER)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZADT0002)
Verify that the accesses to the CA Auditor User data sets are properly restricted.
___ The RACF data set rules for the data sets restricts UPDATE and/or ALTER access to systems programming personnel, security personnel and auditors.
M
Systems Programmer
2016