STIGQter STIGQter: STIG Summary: z/OS BMC CONTROL-M/Restart for ACF2 STIG Version: 6 Release: 5 Benchmark Date: 23 Oct 2015:

BMC CONTROL-M/Restart Archived Sysout data sets must be properly protected.

DISA Rule

SV-32218r4_rule

Vulnerability Number

V-21592

Group Title

ZB000002

Rule Version

ZCTRA002

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Ensure that WRITE and/or greater access to BMC CONTROL-M/Restart Archived Sysout data sets are limited to production control scheduling personnel, scheduled batch users, System Programmers, and the BMC STCs and/or batch users only. READ access can be given to auditors and BMC users.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged.

The installing Systems Programmer will identify if any additional groups have update and/or alter access for specific data sets, and once documented will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

(Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.)

Data sets to be protected will be:
CTRSYS.

The following commands are provided as a sample for implementing data set controls:

$KEY(CTRSYS)
- UID(<syspaudt>) R(A) W(A) A(A) E(A)
- UID(CONTROLM) R(A) W(A) A(A) E(A)
- UID(CONTDAY) R(A) W(A) A(A) E(A)
- UID(<audtaudt>) R(A) E(A)
- UID(<bmcuser>) R(A) E(A)
- UID(<autoaudt>) R(A) W(A) A(A) E(A)
- UID(<pcspaudt>) R(A) W(A) A(A) E(A)

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(CTRUSER)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZCTR0002)

Verify that the accesses to the BMC CONTROL-M/Restart Archived Sysout data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The ACF2 data set access authorizations restrict READ access to auditors and BMC Users.

___ The ACF2 data set access authorizations restrict WRITE and/or greater access to Production Control Scheduling personnel, scheduled batch user(s), systems programming personnel, and the BMC STCs and/or batch users.

Vulnerability Number

V-21592

Documentable

False

Rule Version

ZCTRA002

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(CTRUSER)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZCTR0002)

Verify that the accesses to the BMC CONTROL-M/Restart Archived Sysout data sets are properly restricted. If the following guidance is true, this is not a finding.

___ The ACF2 data set access authorizations restrict READ access to auditors and BMC Users.

___ The ACF2 data set access authorizations restrict WRITE and/or greater access to Production Control Scheduling personnel, scheduled batch user(s), systems programming personnel, and the BMC STCs and/or batch users.

Check Content Reference

M

Responsibility

Systems Programmer

Target Key

2000

Comments