STIGQter STIGQter: STIG Summary: z/OS BMC MAINVIEW for z/OS for ACF2 STIG Version: 6 Release: 8 Benchmark Date: 27 Oct 2017:

BMC Mainview for z/OS Started Task name must be properly identified and/or defined to the system ACP.

DISA Rule

SV-33838r2_rule

Vulnerability Number

V-17452

Group Title

ZB000030

Rule Version

ZMVZA030

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Ensure that a product's Started Task(s) is properly identified and/or defined to the System ACP.

If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes.

Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified.

Example:

SET LID
INSERT MV$CAS STC NO-SMC
INSERT MV$PAS STC NO-SMC
INSERT MV$MVS STC NO-SMC

Check Contents

Refer to the following report produced by the ACF2 Data Collection:

- ACF2CMDS.RPT(ATTSTC)

Insure that the logonids(s) for the BMC Mainview for z/OS started task(s) includes the following:

STC
NO-SMC

Vulnerability Number

V-17452

Documentable

False

Rule Version

ZMVZA030

Severity Override Guidance

Refer to the following report produced by the ACF2 Data Collection:

- ACF2CMDS.RPT(ATTSTC)

Insure that the logonids(s) for the BMC Mainview for z/OS started task(s) includes the following:

STC
NO-SMC

Check Content Reference

M

Responsibility

Information Assurance Officer

Target Key

2093

Comments