SV-33839r1_rule
V-17452
ZB000030
ZMVZR030
CAT II
10
The BMC Mainview for z/OS system programmer and the IAO will ensure that a product's Started Task(s) is properly identified and/or defined to the System ACP.
If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes.
Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified.
A sample is provided here:
au MV$CAS name('CAS, BMC Mainview for z/OS') owner(stc) dfltgrp(stc) nopass
au MV$PAS name('PAS, BMC Mainview for z/OS') owner(stc) dfltgrp(stc) nopass
au MV$MVS name('MVS, BMC Mainview for z/OS') owner(stc) dfltgrp(stc) nopass
Refer to the following report produced by the RACF Data Collection:
- RACFCMDS.RPT(LISTUSER)
The BMC Mainview for z/OS started task(s) and/or batch job userid(s) is defined and is assigned the RACF PROTECTED attribute.
V-17452
False
ZMVZR030
Refer to the following report produced by the RACF Data Collection:
- RACFCMDS.RPT(LISTUSER)
The BMC Mainview for z/OS started task(s) and/or batch job userid(s) is defined and is assigned the RACF PROTECTED attribute.
M
Information Assurance Officer
2093