10
The IAO will ensure that update and allocate access to BMC MAINVIEW for z/OS STC data sets is limited to System Programmers and/or BMC MAINVIEW for z/OS’s STC(s) and/or batch user(s) only. Read access can be given to auditors and authorized users.
The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.
Data sets to be protected will be:
SYS3.BMCVIEW (data sets that are altered by the product’s STCs, this can be more specific)
The following commands are provided as a sample for implementing data set controls:
ad 'SYS3.BMCVIEW.**' uacc(none) owner(sys3) -
audit(failures(read)) -
data('Vendor DS Profile: BMC MAINVIEW for z/OS')
pe 'SYS3.BMCVIEW.**' id(<syspaudt> <tstcaudt> MAINVIEW STCs) acc(a)
pe 'SYS3.BMCVIEW.**' id(<audtaudt> authorized users) acc(r)
setr generic(dataset) refresh
Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(MVZSTC)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZMVZ0001)
Verify that the accesses to the BMC MAINVIEW for z/OS STC data sets are properly restricted.
___ The RACF data set rules for the data sets restricts READ access to auditors and authorized users.
___ The RACF data set rules for the data sets restricts UPDATE and/or ALTER access to systems programming personnel.
___ The RACF data set rules for the data sets restricts UPDATE and/or ALTER access to the BMC MAINVIEW for z/OS’s STC(s) and/or batch user(s).
V-17067
False
ZMVZR001
Refer to the following report produced by the Data Set and Resource Data Collection:
- SENSITVE.RPT(MVZSTC)
Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:
- PDI(ZMVZ0001)
Verify that the accesses to the BMC MAINVIEW for z/OS STC data sets are properly restricted.
___ The RACF data set rules for the data sets restricts READ access to auditors and authorized users.
___ The RACF data set rules for the data sets restricts UPDATE and/or ALTER access to systems programming personnel.
___ The RACF data set rules for the data sets restricts UPDATE and/or ALTER access to the BMC MAINVIEW for z/OS’s STC(s) and/or batch user(s).
M
Systems Programmer
2093