SV-41013r3_rule
V-30971
PDS Construction - Continuously Viewed Carrier
CS-04.01.06
CAT I
10
Interior or Exterior PDS: Continuously viewed Carrier. This is one of five types of Category 2 PDS allowed IAW the CNSSI 7003.
There are four requirements that must be met for this type of distribution system:
1. The transmission line must be under continuous observation, 24 hours per day (including when non-operational).
2. The transmission line must be separated from all non-continuously viewed circuits ensuring an open field of view.
3. There must be an SOP for those responsible for observation of the carrier that includes the requirement to investigate any attempt to disturb the PDS. The requirement must include that appropriate security personnel investigate the area of attempted penetration within 15 minutes of discovery.
4. The PDS must not be located within an Uncontrolled Access Area (UAA).
Interior or Exterior PDS: Continuously viewed Carrier. This is one of five types of Category 2 PDS allowed IAW the CNSSI 7003.
Check to ensure:
1. The transmission line is under continuous observation, 24 hours per day, including when non-operational. (CAT I finding)
2. It is separated from all non-continuously viewed circuits ensuring an open field of view. (CAT III finding)
3. The carrier has an SOP that includes the requirement to investigate any attempt to disturb the PDS. The requirement must include that appropriate security personnel investigate the area of attempted penetration within 15 minutes of discovery. (CAT II finding)
4. The PDS is not located within an Uncontrolled Access Area (UAA). (CAT I)
V-30971
False
CS-04.01.06
Interior or Exterior PDS: Continuously viewed Carrier. This is one of five types of Category 2 PDS allowed IAW the CNSSI 7003.
Check to ensure:
1. The transmission line is under continuous observation, 24 hours per day, including when non-operational. (CAT I finding)
2. It is separated from all non-continuously viewed circuits ensuring an open field of view. (CAT III finding)
3. The carrier has an SOP that includes the requirement to investigate any attempt to disturb the PDS. The requirement must include that appropriate security personnel investigate the area of attempted penetration within 15 minutes of discovery. (CAT II finding)
4. The PDS is not located within an Uncontrolled Access Area (UAA). (CAT I)
M
There are five types of Category 2 PDS: 1. Hardened Carrier (STIG ID: CS-04.01.02) 2. Alarmed Carrier (STIG ID: CS-04.01.08) 3. Continuously Viewed Carrier. (STIG ID: CS-04.01.06) 4. Buried Carrier (STIG ID: CS-04.01.04) and 5. Suspended Carrier (STIG ID: CS-04.01.05).
This Rule covering Continuously Viewed Carriers (STIG ID CS-04.01.06) may be used in conjunction with the other Category 2 carriers. Different requirements apply to each type of Category 2 carrier and must be assessed under their respective STIG Rules.