STIGQter STIGQter: STIG Summary: Video Services Policy STIG Version: 1 Release: 11 Benchmark Date: 24 Apr 2020:

An IP-based VTC system implementing a single CODEC supporting conferences on multiple networks having different classification levels (i.e., unclassified, SECRET, TOP SECRET, TS-SCI) must support Periods Processing by connecting the CODEC to one network at a time, matching the classification level of the session to the classification level of the network.

DISA Rule

SV-55745r1_rule

Vulnerability Number

V-43016

Group Title

RTS-VTC 7020 [IP]

Rule Version

RTS-VTC 7020

Severity

CAT I

CCI(s)

Weight

10

Fix Recommendation

Obtain and install an approved A/B, A/B/C, or A/B/C/D switch. Alternately, manually connect the VTC CODEC to one network at a time through the use of a single patch cord.

Check Contents

Review the VTC system architecture to verify that an approved A/B, A/B/C, or A/B/C/D switch is present and properly cabled. Alternately, validate that the VTC CODEC is manually connected to one network at a time through the use of a single patch cord. If neither is in place, this is a finding.

Vulnerability Number

V-43016

Documentable

False

Rule Version

RTS-VTC 7020

Severity Override Guidance

Review the VTC system architecture to verify that an approved A/B, A/B/C, or A/B/C/D switch is present and properly cabled. Alternately, validate that the VTC CODEC is manually connected to one network at a time through the use of a single patch cord. If neither is in place, this is a finding.