STIGQter STIGQter: STIG Summary: Microsoft Internet Explorer 11 Security Technical Implementation Guide Version: 1 Release: 19 Benchmark Date: 24 Jul 2020:

Logon options must be configured to prompt (Internet zone).

DISA Rule

SV-59387r1_rule

Vulnerability Number

V-46523

Group Title

DTBI046-IE11-User Authentication-Logon - Internet

Rule Version

DTBI046-IE11

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Set the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Internet Explorer -> Internet Control Panel -> Security Page -> Internet Zone -> 'Logon options' to 'Enabled', and select 'Prompt for user name and password' from the drop-down box.

Check Contents

The policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Internet Explorer -> Internet Control Panel -> Security Page -> Internet Zone -> 'Logon options' must be 'Enabled', and 'Prompt for user name and password' selected from the drop-down box. Procedure: Use the Windows Registry Editor to navigate to the following key: HKLM\Software\Policies\Microsoft\Windows\CurrentVersion\Internet Settings\Zones\3 Criteria: If the value "1A00" is REG_DWORD = 65536 (decimal), this is not a finding.

Vulnerability Number

V-46523

Documentable

False

Rule Version

DTBI046-IE11

Severity Override Guidance

The policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Internet Explorer -> Internet Control Panel -> Security Page -> Internet Zone -> 'Logon options' must be 'Enabled', and 'Prompt for user name and password' selected from the drop-down box. Procedure: Use the Windows Registry Editor to navigate to the following key: HKLM\Software\Policies\Microsoft\Windows\CurrentVersion\Internet Settings\Zones\3 Criteria: If the value "1A00" is REG_DWORD = 65536 (decimal), this is not a finding.