SV-59503r1_rule
V-46639
DTBI390-IE11-Script initiated windows - Restricted Sites
DTBI390-IE11
CAT II
10
Set the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Internet Explorer -> Internet Control Panel -> Security Page -> Restricted Sites Zone -> 'Allow script-initiated windows without size or position constraints' to 'Enabled', and select 'Disable' from the drop-down box.
The policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Internet Explorer -> Internet Control Panel -> Security Page -> Restricted Sites Zone -> 'Allow script-initiated windows without size or position constraints' must be 'Enabled', and 'Disable' selected from the drop-down box. Procedure: Use the Windows Registry Editor to navigate to the following key: HKLM\Software\Policies\Microsoft\Windows\CurrentVersion\Internet Settings\Zones\4 Criteria: If the value "2102" is REG_DWORD = 3, this is not a finding.
V-46639
False
DTBI390-IE11
The policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Internet Explorer -> Internet Control Panel -> Security Page -> Restricted Sites Zone -> 'Allow script-initiated windows without size or position constraints' must be 'Enabled', and 'Disable' selected from the drop-down box. Procedure: Use the Windows Registry Editor to navigate to the following key: HKLM\Software\Policies\Microsoft\Windows\CurrentVersion\Internet Settings\Zones\4 Criteria: If the value "2102" is REG_DWORD = 3, this is not a finding.
M
2589