STIGQter STIGQter: STIG Summary: Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide Version: 1 Release: 3 Benchmark Date: 25 Oct 2019:

The Arista Multilayer Switch must display the Standard Mandatory DoD Notice and Consent Banner before granting access to the device.

DISA Rule

SV-75299r1_rule

Vulnerability Number

V-60843

Group Title

SRG-APP-000068-NDM-000215

Rule Version

AMLS-NM-000160

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the switch to display the Standard DoD Notice and Consent banner.

To configure the banner, enter the following commands from the configuration mode interface. Replace the bracketed data with the DoD Banner.

switch(config)#banner login
[DoD Banner]
EOF

Check Contents

Review the device configuration and verify display of the Standard DoD Notice and Consent Banner.

If the banner is not displayed, this is a finding.

To verify the device is configured to display the DoD Banner, review the running configuration with the "show running-config" command. Identify the section "banner login" and verify the standard DoD Banner is displayed.

Vulnerability Number

V-60843

Documentable

False

Rule Version

AMLS-NM-000160

Severity Override Guidance

Review the device configuration and verify display of the Standard DoD Notice and Consent Banner.

If the banner is not displayed, this is a finding.

To verify the device is configured to display the DoD Banner, review the running configuration with the "show running-config" command. Identify the section "banner login" and verify the standard DoD Banner is displayed.

Check Content Reference