SV-77257r1_rule
V-62767
SRG-APP-000412-NDM-000331
PANW-NM-000118
CAT I
10
Go to Device >> Setup >> Operations; in the Miscellaneous pane, select SNMP Setup.
In the SNMP Setup window, complete the required fields.
For the Version, select V3.
Configure a view and assign it to a user.
In the upper half of the SNMP Setup window, select "Add".
In the Views window, complete the required fields; obtain the values for the OID and Mask fields from product documentation or vendor support.
In the Option field, select "include".
Select "OK".
In the lower half of the SNMP Setup window, select "Add".
Complete the required fields.
Select "OK".
Obtain the engineID of the Palo Alto device by issuing an SNMPv3 GET from the management workstation against the OID of the Palo Alto device.
Configure the SNMPv3 Trap Server profile; go to Device >> Server Profiles >> SNMP Trap; select "Add".
In the SNMP Trap Server Profile window, complete the required fields.
Select "OK".
Commit changes by selecting "Commit" in the upper-right corner of the screen.
Select "OK" when the confirmation dialog appears.
Go to Device >> Setup >> Operations; in the Miscellaneous pane, select SNMP Setup.
In the SNMP Setup window, check if SNMP V3 is selected.
If V3 is not selected, this is a finding.
Go to Device >> Server Profiles >> SNMP Trap.
View the list of configured SNMP servers; if the Version is not "v3", this is a finding.
V-62767
False
PANW-NM-000118
Go to Device >> Setup >> Operations; in the Miscellaneous pane, select SNMP Setup.
In the SNMP Setup window, check if SNMP V3 is selected.
If V3 is not selected, this is a finding.
Go to Device >> Server Profiles >> SNMP Trap.
View the list of configured SNMP servers; if the Version is not "v3", this is a finding.