SV-79641r1_rule
V-65151
SRG-APP-000372-NDM-000297
WSDP-NM-000099
CAT III
10
Configure the DataPower Gateway to synchronize internal information system clocks to the authoritative time source (NTP servers).
In the DataPower WebGUI, go to Network >> Interface >> NTP Service. Specify the IP addresses of several approved NTP servers. The refresh interval may be defined at any value between 60 and 86400 seconds.
Using the DataPower web interface, go to Network >> Interface >> NTP Service. Confirm that the Administrative state is enabled, NTP Servers are configured, and that the Refresh Interval is set to 2040 seconds or less. If it is not, this is a finding.
V-65151
False
WSDP-NM-000099
Using the DataPower web interface, go to Network >> Interface >> NTP Service. Confirm that the Administrative state is enabled, NTP Servers are configured, and that the Refresh Interval is set to 2040 seconds or less. If it is not, this is a finding.
M
2861