SV-80731r2_rule
V-66241
SRG-APP-000357-NDM-000293
HFFS-ND-000095
CAT II
10
Configure the HP FlexFabric Switch to allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.
[HP] info-center security-logfile size-quota 10
Note: The security logfile size in set in MB
Enter the command display logfile summary to verify audit record storage has been allocated in accordance with the organization-defined audit record storage requirements.
If the switch has not been configured to allocate audit record storage in accordance with the organization-defined audit record storage requirements, this is a finding.
V-66241
False
HFFS-ND-000095
Enter the command display logfile summary to verify audit record storage has been allocated in accordance with the organization-defined audit record storage requirements.
If the switch has not been configured to allocate audit record storage in accordance with the organization-defined audit record storage requirements, this is a finding.
M
2971