SV-80745r1_rule
V-66255
SRG-APP-000375-NDM-000300
HFFS-ND-000102
CAT II
10
Configure timestamp on the logs on the HP FlexFabric Switch:
[HP] info-center timestamp date
By default, the device uses internal system clocks to generate time stamps for audit records in the date format - MMM DD hh:mm:ss:xxx YYYY which provides required granularity.
Check if info-center is configured to provide timestamp:
[HP] display info-center
Information Center: Enabled
Console: Enabled
Monitor: Enabled
Log host: Enabled
192.100.50.27,
port number: 514, host facility: local7
Log buffer: Enabled
Max buffer size 1024, current buffer size 512
Current messages 66, dropped messages 0, overwritten messages 0
Log file: Enabled
Security log file: Enabled
Information timestamp format:
Log host: Date
Other output destination: Date
Check logfile content to determine if the time stamp is present:
<HP> cd logfile/
<HP> more logfile.log
%@9377%Jan 20 23:31:03:567 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is dis info-center
%@9378%Jan 20 23:31:09:342 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is qui
If the HP FlexFabric Switch is not configured to enable timestamp, this is a finding.
V-66255
False
HFFS-ND-000102
Check if info-center is configured to provide timestamp:
[HP] display info-center
Information Center: Enabled
Console: Enabled
Monitor: Enabled
Log host: Enabled
192.100.50.27,
port number: 514, host facility: local7
Log buffer: Enabled
Max buffer size 1024, current buffer size 512
Current messages 66, dropped messages 0, overwritten messages 0
Log file: Enabled
Security log file: Enabled
Information timestamp format:
Log host: Date
Other output destination: Date
Check logfile content to determine if the time stamp is present:
<HP> cd logfile/
<HP> more logfile.log
%@9377%Jan 20 23:31:03:567 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is dis info-center
%@9378%Jan 20 23:31:09:342 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is qui
If the HP FlexFabric Switch is not configured to enable timestamp, this is a finding.
M
2971