STIGQter STIGQter: STIG Summary: HPE 3PAR StoreServ 3.2.x Security Technical Implementation Guide Version: 1 Release: 3 Benchmark Date: 28 Jul 2017:

The storage system must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

DISA Rule

SV-85137r1_rule

Vulnerability Number

V-70515

Group Title

SRG-OS-000359-GPOS-00146

Rule Version

HP3P-32-001701

Severity

CAT III

CCI(s)

Weight

10

Fix Recommendation

Configure the "Timezone" field by first identifying the time zone identifier.

Enter the command to list available time zone settings:

cli% setdate -tzlist

If UTC is to be set, then use the following command:

cli% setdate -tz Etc/UTC

Check Contents

Verify the "Timezone" field is configured by entering the following command:

cli% showdate
Node Date
0 2016-05-18 23:46:29 UTC (Etc/UTC)
1 2016-05-18 23:46:37 UTC (Etc/UTC)

If the output does not match the required time zone, this is a finding.

Vulnerability Number

V-70515

Documentable

False

Rule Version

HP3P-32-001701

Severity Override Guidance

Verify the "Timezone" field is configured by entering the following command:

cli% showdate
Node Date
0 2016-05-18 23:46:29 UTC (Etc/UTC)
1 2016-05-18 23:46:37 UTC (Etc/UTC)

If the output does not match the required time zone, this is a finding.

Check Content Reference

M

Target Key

3013

Comments