STIGQter STIGQter: STIG Summary: Microsoft Project 2016 Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 14 Nov 2016:

Untrusted intranet zone access to Project servers must not be allowed.

DISA Rule

SV-85351r1_rule

Vulnerability Number

V-70727

Group Title

SRG-APP-000210

Rule Version

DTOO346

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Set the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2016 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" to "Disabled".

Check Contents

Verify the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2016 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" is set to "Disabled".

Procedure: Use the Windows Registry Editor to navigate to the following key:

HKCU\Software\Policies\Microsoft\Office\16.0\ms project\security

Criteria: If the value TrustWSS is REG_DWORD = 0, this is not a finding.

Vulnerability Number

V-70727

Documentable

False

Rule Version

DTOO346

Severity Override Guidance

Verify the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2016 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" is set to "Disabled".

Procedure: Use the Windows Registry Editor to navigate to the following key:

HKCU\Software\Policies\Microsoft\Office\16.0\ms project\security

Criteria: If the value TrustWSS is REG_DWORD = 0, this is not a finding.

Check Content Reference

M

Target Key

3127

Comments