SV-87765r1_rule
V-73113
NET-SDN-024
NET-SDN-024
CAT III
10
Configure all hypervisor hosts and VXLAN-enabled switches so the VTEP will be dual-homed to two physical network nodes.
In the case of the VXLAN-enabled switch, the VTEP will be the loopback interface; hence, dual-homing can be achieved by having two links going upstream to two switches or to two routers.
The hypervisor can use network interface card (NIC) teaming for the VTEP interface, with each link connected to an access switch.
Review the VXLAN topology and the configuration of all hypervisor hosts and VXLAN-enabled switches to verify that every VTEP is dual-homed to two physical network nodes.
If any VTEPs are not dual-homed to two physical network nodes, this is a finding.
Note: This requirement is only applicable to VNIs that must be defined on each VXLAN-enabled switch. In addition, this requirement is applicable to the implementation of technologies similar to VXLAN (e.g., NVGRE, STT) for the purpose of transporting traffic between virtual machines residing on different physical hosts.
V-73113
False
NET-SDN-024
Review the VXLAN topology and the configuration of all hypervisor hosts and VXLAN-enabled switches to verify that every VTEP is dual-homed to two physical network nodes.
If any VTEPs are not dual-homed to two physical network nodes, this is a finding.
Note: This requirement is only applicable to VNIs that must be defined on each VXLAN-enabled switch. In addition, this requirement is applicable to the implementation of technologies similar to VXLAN (e.g., NVGRE, STT) for the purpose of transporting traffic between virtual machines residing on different physical hosts.
M
3089