The MQ Appliance network device must be configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources.

DISA Rule

SV-89673r1_rule

Vulnerability Number

V-74999

Group Title

SRG-APP-000373-NDM-000298

Rule Version

MQMH-ND-001080

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Log on to the MQ Appliance WebGUI as a privileged user.

Click on the Network icon (third from the top).
Select "Interface/NTP Service".
Click the "Add" button to add multiple NTP servers.
Click "Enable administrative state".
Click the "Apply" button.

Add one or more additional NTP servers, at least one of which is from a different geographic region.

The result should be: "Status:up"

Click "Save configuration".

Check Contents

Log on to the MQ Appliance WebGUI as a privileged user.

On the Manage Appliance tab, select Network >> Interface/NTP Service.

Verify:
- NTP server destinations are configured;
* The NTP servers are located in different geographic regions; and
* Status (at the top of the page) is "up".

If any is not true, this is a finding.

Vulnerability Number

V-74999

Documentable

False

Rule Version

MQMH-ND-001080

Severity Override Guidance

Log on to the MQ Appliance WebGUI as a privileged user.

On the Manage Appliance tab, select Network >> Interface/NTP Service.

Verify:
- NTP server destinations are configured;
* The NTP servers are located in different geographic regions; and
* Status (at the top of the page) is "up".

If any is not true, this is a finding.