STIGQter STIGQter: STIG Summary: DBN-6300 NDM Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 12 Sep 2017:

The DBN-6300 must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC).

DISA Rule

SV-91689r1_rule

Vulnerability Number

V-76993

Group Title

SRG-APP-000374-NDM-000299

Rule Version

DBNW-DM-000103

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the time zone to "UTC".

Navigate to Settings >> Initial Configuration >> Time and click on "NTP".

Click on the drop-down box next to the "Time Zone" label.

Select "UTC" underneath the "Etc" category.

Click on "Commit".

Check Contents

Verify the time zone is configured for "UTC".

Navigate to Settings >> Initial Configuration >> Time.

View the "Time Zone" box.

If the Time Zone is not set to "UTC", this is a finding.

Vulnerability Number

V-76993

Documentable

False

Rule Version

DBNW-DM-000103

Severity Override Guidance

Verify the time zone is configured for "UTC".

Navigate to Settings >> Initial Configuration >> Time.

View the "Time Zone" box.

If the Time Zone is not set to "UTC", this is a finding.

Check Content Reference