STIGQter STIGQter: STIG Summary: DBN-6300 NDM Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 12 Sep 2017:

The DBN-6300 must generate audit records when concurrent logons from different workstations occur.

DISA Rule

SV-91709r1_rule

Vulnerability Number

V-77013

Group Title

SRG-APP-000506-NDM-000323

Rule Version

DBNW-DM-000126

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure the DBN-6300 to be connected to the syslog server. Also configure the DBN-6300 to include audit records in the syslog message feed.

Navigate to Settings >> Advanced >> Syslog.

Enter the syslog connection information (port and IP address) and push the "enabled" button for both "TCP" and "enable".

Navigate to Settings >> Advanced >> Audit Log.

Verify that the Audit Syslog, "Use System Syslog" button is set to "Yes" and the Audit Configuration Categories are all checked for Audit Log, Syslog, and Audit Console.

If the "Use System Syslog" button is not set to "Yes", press the "Yes" button.

Click on "Commit".

Check Contents

Verify the DBN-6300 is connected to the syslog server.

Navigate to Settings >> Advanced >> Syslog.

Verify that the syslog services are set to "on", the syslog server information is valid, and the syslog server has connected.

Navigate to Settings >> Advanced >> Audit Log.

Verify that the Audit Syslog, "Use System Syslog" button is set to "Yes" and the Audit Configuration Categories are all checked for Audit Log, Syslog, and Audit Console.

Following this verification, a user should log on from two different workstations. Confirm the presence of a syslog message on the syslog server containing logon information pertinent to logons from the same user from two different workstations.

If the DBN-6300 is not connected to the syslog server, or if the syslog server is connected but the message containing the information pertinent to a user logging on concurrently from two different workstations is not there, this is a finding.

Vulnerability Number

V-77013

Documentable

False

Rule Version

DBNW-DM-000126

Severity Override Guidance

Verify the DBN-6300 is connected to the syslog server.

Navigate to Settings >> Advanced >> Syslog.

Verify that the syslog services are set to "on", the syslog server information is valid, and the syslog server has connected.

Navigate to Settings >> Advanced >> Audit Log.

Verify that the Audit Syslog, "Use System Syslog" button is set to "Yes" and the Audit Configuration Categories are all checked for Audit Log, Syslog, and Audit Console.

Following this verification, a user should log on from two different workstations. Confirm the presence of a syslog message on the syslog server containing logon information pertinent to logons from the same user from two different workstations.

If the DBN-6300 is not connected to the syslog server, or if the syslog server is connected but the message containing the information pertinent to a user logging on concurrently from two different workstations is not there, this is a finding.

Check Content Reference

M

Target Key

2947

Comments