SV-93733r2_rule
V-79027
SRG-APP-000516-AS-000237
BEMS-00-013700
CAT II
10
Configure BEMS with an inactivity timeout of 15 minutes or less.
1. Find the xml file "jetty.xml" located in the BEMS install directory on the BEMS host Windows server.
2. Find the "maxIdleTime" field and set it to 900 or less (seconds). (Note: “idelTimeout” may be the field and time may be in milliseconds, depending on the version of BEMS. In this case, the value is 900000.)
3. Save the file.
4. Restart the BEMS server.
Verify the BEMS inactivity timeout is set to 15 minutes or less as follows:
1. Find the xml file "jetty.xml" located in the BEMS install directory on the BEMS host Windows server.
2. Find the "maxIdleTime" field. (Note: “idelTimeout” may be the field, depending on the version of BEMS)
3. Verify it is set to 900 or less (seconds). (Note: time may be in milliseconds, depending on the version of BEMS. In this case, the value is 900000.)
If the BEMS inactivity timeout is not set to 15 minutes (900 seconds) or less, this is a finding.
V-79027
False
BEMS-00-013700
Verify the BEMS inactivity timeout is set to 15 minutes or less as follows:
1. Find the xml file "jetty.xml" located in the BEMS install directory on the BEMS host Windows server.
2. Find the "maxIdleTime" field. (Note: “idelTimeout” may be the field, depending on the version of BEMS)
3. Verify it is set to 900 or less (seconds). (Note: time may be in milliseconds, depending on the version of BEMS. In this case, the value is 900000.)
If the BEMS inactivity timeout is not set to 15 minutes (900 seconds) or less, this is a finding.