STIGQter STIGQter: STIG Summary: VMware vRealize Operations Manager 6.x SLES Security Technical Implementation Guide Version: 1 Release: 1 Benchmark Date: 28 Sep 2018:

The SLES for vRealize must not use UDP for NIS/NIS+.

DISA Rule

SV-99169r1_rule

Vulnerability Number

V-88519

Group Title

SRG-OS-000096-GPOS-00050

Rule Version

VROM-SL-000525

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Configure SLES for vRealize to not use UDP for NIS and NIS+. Consult vendor documentation for the required procedure.

Check Contents

If SLES for vRealize does not use NIS or NIS+, this is not applicable.

Check if NIS or NIS+ is implemented using UDP:

# rpcinfo -p | grep yp | grep udp

If NIS or NIS+ is implemented using UDP, this is a finding.

Vulnerability Number

V-88519

Documentable

False

Rule Version

VROM-SL-000525

Severity Override Guidance

If SLES for vRealize does not use NIS or NIS+, this is not applicable.

Check if NIS or NIS+ is implemented using UDP:

# rpcinfo -p | grep yp | grep udp

If NIS or NIS+ is implemented using UDP, this is a finding.

Check Content Reference

M